Search results for "Electronic Load"
showing 7 items of 7 documents
Design and Development of a Labview Application for the Measurement of the Complex Impedance of a Fuel Cell in Real Time
2014
International audience; To optimize the performance of fuel cells and to deepen the knowledge of their behavior, it is necessary to make measurements in real time. To run such a measure, it is necessary to use specific software and hardware tools to instrumentation fuel cells. In this context, we presented the steps of designing and developing an application for the measurement of the complex impedance by electrochemical impedance spectroscopy method (EIS) using LabVIEW® software. The experimental results are obtained using a Ballard Nexa® PEM fuel cell, an electronic load produced in our laboratory and application developed by the LabVIEW® software.
Outdoor Performance of 10 year Old a-Si and Poly-Si Modules in southern Norway conditions
2012
The outdoor performance of 10 years modules has been measured in southern Norway conditions. For this study, Poly-Si and a-Si modules are selected and the measurements are carried out using a portable electronic load. The I–V characteristics and maximum power have been recorded for several modules of each technology. It is found that Poly-Si modules perform very well even after 10 years of span whereas some of a-Si modules have visual degradation which causes significant power losses. The experimentally outdoor monitored values of P mp , V mp , short circuit current (I sc ), Open circuit voltage (V oc ) and efficiency for different modules are compared with manufacturer's values.
A standard-compliant prototype for PV module curve detection
2014
In this paper, a prototype for PV module curve detection which features low cost and size and ensures high accuracy is proposed. The proposed architecture is based on a buck-boost converter in open-loop configuration. The proposed architecture is fully compliant with actual standard IEC60904. The duty-cycle control algorithm and its own effects on system performances are accurately investigated. The comparison of different duty-cycle patterns is carried out and performance evaluation is performed. Simulation results are shown to perform a valuable comparison of control algorithms. Preliminary experimental results on a laboratory prototype are presented.
A device for PV modules I-V characteristic detection
2013
In this paper an electronic load suitable for the PV module I-V characteristic curve fast detection is presented. This device is designed in agreement with the IEC 82 Techinical Committee Standard since it allows the detection of the characteristic starting from voltage values even lower than 3% of the PV module open circuit voltage. The device main features are short time characteristc detection (2 s), limited ripple of the detected characteristic and low cost. Its validation is carried out by comparing measured data with data from simulations. Simulations are carried out considering two different commercial PV modules and by implementing in Matlab-Simulink environment the four lumped para…
Design, sizing and set up of a specific low cost electronic load for PV modules characterization
2013
In this paper, the design, sizing and set-up of a specific low cost electronic load, based on a DC-DC step-down converter, suitable for the PV module I - V characteristic curves determination, is described. In particular, for its set up, a low cost and user friendly micro-controller has been employed in order to generate the PWM signal. The measures carried out connecting the electronic load prototype to a commercial PV module are here presented and discussed. The conceived electronic load has allowed the determination of 80% of the PV module characteristic curves in 2 s. This low measurement time, lower than the time intervals in which weather conditions may change, allows to assume as con…
A DC-DC power converter for PV module characterization
2014
In this paper, a standard-compliant electronic load setup for PV module curve detection which features high accuracy, low cost and components count is proposed. The proposed device is based on a DC-DC power converter in open-loop configuration. The proposed system is designed according to regulation constraints in order to achieve high performances in curve detection. Design criteria are discussed. The model is implemented in PSIM environment. Simulation based on data input of a commercial PV Conergy E215P module are carried out under several environmental conditions to show the accuracy of the proposed electronic load. Simulation results are reported.
Design and control of an innovative electronic load for the photovoltaic module characterization
2016
The paper proposes a new electronic load setup for a fast, low-cost and standard-compliant characterization of a photovoltaic module. The approach is based on the use of a DC-DC converter, exploiting its ability to emulate a resistor. In particular, a Buck-Boost converter topology is employed. The model is implemented in the Simulink/SimPower System environment. A commercial PV Conergy E215P photovoltaic module is used in order to evaluate the performances of the proposed electronic load and to validate the proposed approach.